Skip to main navigation Skip to search Skip to main content

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Su Young Lee
  • , Chunmei Piao
  • , Seong Joo Heo
  • , Jai Young Koak
  • , Joo Hee Lee
  • , Tae Hyung Kim
  • , Myung Joo Kim
  • , Ho Beom Kwon
  • , Seong Kyun Kim
  • Seoul National University
  • University of Ulsan
  • University of Southern California

Research output: Contribution to journal › Article › peer-review

12 Scopus citations

Abstract

Purpose: The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. Materials and Methods: Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. Results: The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ≥.05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). Conclusion: Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

Original languageEnglish
Pages (from-to)148-153
Number of pages6
JournalJournal of Advanced Prosthodontics
Volume2
Issue number4
DOIs
StatePublished - 2010

Keywords

  • Cr:YSGG laser
  • Energy
  • Er
  • Insertion torque resonance frequency analysis
  • Titanium implant

Fingerprint

Dive into the research topics of 'A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables'. Together they form a unique fingerprint.

Cite this