Skip to main navigation Skip to search Skip to main content

Accuracy of Measurements of the Structural Reserve for Upper Limb Function in Patients With Moderate-to-Severe Stroke

  • Catholic Univ. of Korea Coll. Med.
  • Catholic University of Korea

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Background: The structural integrity of the corticospinal tract (CST) is an important biomarker of poststroke upper limb recovery. Injured CST undergoes Wallerian degeneration rostrocaudally during the first few months. However, there is no standardized measurement of the structural integrity of the CST. This study aimed to determine the measurement accuracy of the structural integrity of the CST. Methods: This cross-sectional study included 50 consecutive patients with middle cerebral artery stroke who underwent diffusion tensor imaging upon transfer from the acute stroke unit to the inpatient rehabilitation facility (2018-2022). We evaluated hemiplegic upper limb function using Shoulder Abduction and Finger Extension (SAFE) scores. Fractional anisotropy values representing the structural integrity of the CST were evaluated using 4 region of interest-based and 2 tract-based measurements, including the posterior limb of internal capsule, cerebral peduncle, pons, pontomedullary junction, entire CST, and CST in the brainstem. Multivariate linear regression models and the area under the curve (AUC) were used to determine measurement accuracy for hemiplegic upper limb function. Results: The structural integrity of the CST at the pontomedullary junction showed the highest explanatory power, followed by the entire CST, in the multivariate linear regression models (adjusted R2=0.459 and 0.425, respectively). The structural integrity of the CST at the pontomedullary junction also showed the highest AUC, followed by the entire CST, in discriminating patients with a SAFE score of <8 or 5 from those with SAFE ≥8 or 5 (SAFE <8: AUC, 0.90 [95% CI, 0.80-1.00]; AUC, 0.83 [0.66-0.99]; SAFE <5: AUC, 0.87 [0.77-0.96]; AUC, 0.83, [0.72-0.95], respectively). Conclusions: The structural integrity of the CST measured at the pontomedullary junction or entire CST demonstrated the highest accuracy for hemiplegic upper limb function in the subacute phase of stroke.

Original languageEnglish
Pages (from-to)1854-1862
Number of pages9
JournalStroke
Volume54
Issue number7
DOIs
StatePublished - 1 Jul 2023

Bibliographical note

Publisher Copyright:
© 2023 American Heart Association, Inc.

Keywords

  • anisotropy
  • biomarker
  • corticospinal tract
  • diffusion tensor imaging
  • stroke

Fingerprint

Dive into the research topics of 'Accuracy of Measurements of the Structural Reserve for Upper Limb Function in Patients With Moderate-to-Severe Stroke'. Together they form a unique fingerprint.

Cite this