TY - JOUR
T1 - Application of calculated panel reactive antibody using HLA frequencies in Koreans
AU - Jang, Ji Young
AU - Kim, Yoon Joo
AU - Kim, Yonggoo
AU - Park, Yeon Joon
AU - Han, Kyungja
AU - Oh, Eun Jee
PY - 2012/1
Y1 - 2012/1
N2 - Background: Introduction of the Luminex panel reactive antibody (PRA)-single antigen (SA) assay has increased the detection rates of unacceptable antigens in sensitized patients; the calculated PRA (CPRA) level represents the percentage of actual organ donors that express 1 or more of these unacceptable antigens. We developed a CPRA calculator based on the HLA frequencies in Koreans to measure sensitization levels in Korean patients. Methods: To develop the calculator, we obtained the HLA-A, HLA-B, and HLA-DR phenotypes of 1,622 Koreans, and compared these with previously reported frequencies in Koreans. Sera from patients awaiting kidney transplantation were tested for HLA antibodies by Luminex PRA-screen, PRA-identification (ID), and PRA-SA assays. The measured %PRA from the PRA-screen (N=55) and PRA-ID (N=71) were compared to the %CPRA for the unacceptable antigens obtained from PRA-SA. Results: Phenotype frequencies used for the CPRA calculator agreed with previously reported data. The concordance rates among the 3 PRA methods for the detection of class I and class II antibodies were 76.1-81.8% (kappa, 0.519-0.636) and 72.7-83.6% (0.463- 0.650), respectively. For the detection of broadly sensitized sera (<50% or >80%), the concordance rates were over 80%. In sera with 80-100% CPRA, 91.7% and 94.4% of the samples had concordant results (80-100% PRA) in the PRA-screen and PRA-ID assay, respectively. Conclusions: Although further clinical studies are required to confirm the benefits of CPRA values, adoption of CPRA analysis based on HLA frequencies in Koreans may be useful for sensitization measurements and organ-allocation algorithms.
AB - Background: Introduction of the Luminex panel reactive antibody (PRA)-single antigen (SA) assay has increased the detection rates of unacceptable antigens in sensitized patients; the calculated PRA (CPRA) level represents the percentage of actual organ donors that express 1 or more of these unacceptable antigens. We developed a CPRA calculator based on the HLA frequencies in Koreans to measure sensitization levels in Korean patients. Methods: To develop the calculator, we obtained the HLA-A, HLA-B, and HLA-DR phenotypes of 1,622 Koreans, and compared these with previously reported frequencies in Koreans. Sera from patients awaiting kidney transplantation were tested for HLA antibodies by Luminex PRA-screen, PRA-identification (ID), and PRA-SA assays. The measured %PRA from the PRA-screen (N=55) and PRA-ID (N=71) were compared to the %CPRA for the unacceptable antigens obtained from PRA-SA. Results: Phenotype frequencies used for the CPRA calculator agreed with previously reported data. The concordance rates among the 3 PRA methods for the detection of class I and class II antibodies were 76.1-81.8% (kappa, 0.519-0.636) and 72.7-83.6% (0.463- 0.650), respectively. For the detection of broadly sensitized sera (<50% or >80%), the concordance rates were over 80%. In sera with 80-100% CPRA, 91.7% and 94.4% of the samples had concordant results (80-100% PRA) in the PRA-screen and PRA-ID assay, respectively. Conclusions: Although further clinical studies are required to confirm the benefits of CPRA values, adoption of CPRA analysis based on HLA frequencies in Koreans may be useful for sensitization measurements and organ-allocation algorithms.
KW - Calculated panel reactive antibody (CPRA)
KW - HLA antibody
KW - Panel reactive antibody (PRA)
KW - Sensitization
KW - Transplantation
KW - Unacceptable antigen
UR - https://www.scopus.com/pages/publications/84859617228
U2 - 10.3343/alm.2012.32.1.66
DO - 10.3343/alm.2012.32.1.66
M3 - Article
C2 - 22259781
AN - SCOPUS:84859617228
SN - 2234-3806
VL - 32
SP - 66
EP - 72
JO - Annals of Laboratory Medicine
JF - Annals of Laboratory Medicine
IS - 1
ER -