Skip to main navigation Skip to search Skip to main content

Assessment of M-protein quantification using capillary electrophoresis and immunosubtraction-based integration in clinical samples with low M-protein concentrations

  • Catholic Univ. of Korea Coll. Med.

Research output: Contribution to journal › Article › peer-review

4 Scopus citations

Abstract

Objectives: Quantification of monoclonal protein (M-protein) by serum protein electrophoresis (SPE) is indispensable for diagnosing and monitoring monoclonal gammopathies. However, quantification of small and beta migrating M-proteins is challenging because of overlapping non-immunoglobulin and/or polyclonal immunoglobulin protein fractions. We compared a new integration method based on immunosubtraction (IS-CE) using capillary zone electrophoresis (CZE) against the routine method, which includes a combination of perpendicular drop (0.4%), corrected perpendicular drop (1%) and tangent skimming (98.5%). Design & methods: The proposed method of M-protein quantification involves calculating the difference in area under the curve between the SPE and a class-specific IS-CE trace. We analyzed the difference in estimated M-protein concentrations obtained with the new method and routine integration methods using 913 samples. For IgA M-proteins at < 10 g/L, the estimated M-protein concentrations were compared with the total IgA concentration. Results: The median M-protein concentration of 913 consecutive samples was 6.2 g/L (IQR 2.1–14.3 g/L). The median and median % difference between the two integration methods was 0.68 g/L (IQR 0.01–1.55 g/L) and 10.9% (IQR 0.18–38.7%), showing a larger estimated M-protein concentration with the new method. More than 25% difference was observed in 38% of the samples and was associated with lower total protein concentration, lower M-protein concentration, IgA and IgM heavy chain isotypes, and beta- or beta-gamma migration. When 161 samples with IgA M-protein < 10 g/L were compared against total IgA concentration, the median bias of the new method was smaller compared to that of the existing method (-0.95 g/L vs. −1.3 g/L, P < 0.0001). Conclusions: The use of IS based integration using CZE and IS-CE is promising especially for small and beta migrating M-proteins.

Original languageEnglish
Pages (from-to)7-12
Number of pages6
JournalClinical Biochemistry
Volume107
DOIs
StatePublished - Sep 2022

Bibliographical note

Publisher Copyright:
© 2022

Keywords

  • Immunosubtraction
  • M-protein
  • Monoclonal gammopathy
  • Multiple myeloma
  • Serum protein electrophoresis

Fingerprint

Dive into the research topics of 'Assessment of M-protein quantification using capillary electrophoresis and immunosubtraction-based integration in clinical samples with low M-protein concentrations'. Together they form a unique fingerprint.

Cite this