Skip to main navigation Skip to search Skip to main content

Astigmatic correction by intrastromal astigmatic keratotomy during femtosecond laser–assisted cataract surgery: Factors in outcomes

  • Catholic Univ. of Korea Coll. Med.

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

Purpose: To evaluate the 6-month outcomes of femtosecond laser astigmatic keratotomy (AK) combined with femtosecond laser–assisted cataract surgery and identify factors affecting the efficacy of astigmatic correction. Setting: Seoul St. Mary's Hospital, Catholic University of Korea, Seoul, South Korea. Design: Retrospective case series. Methods: Femtosecond laser AK was performed during femtosecond laser–assisted cataract surgery. The keratometric astigmatism, refractive cylinder, corneal hysteresis (CH), and corneal resistance factor (CRF) were measured preoperatively and postoperatively at 1 week, 2 months, and 6 months. Vector analysis to evaluate the 6-month outcomes of femtosecond laser AK and univariable regression analysis to determine the factors influencing the correction index were performed. Results: The study enrolled 89 eyes of 89 patients. The stigmatism type, CH, CRF, and absolute angle of error showed significant correlations with the correction index (P =.041, P =.029, P =.044, and P <.001, respectively). There was a significant difference in the correction index and no difference in keratometric astigmatism between with-the-rule (WTR), against-the-rule (ATR), and oblique astigmatism (P =.044). The keratometric astigmatism with ATR and oblique astigmatism (0.66 diopter [D] ± 0.42 [SD] and 0.46 ± 0.27 D, respectively) was significantly lower than the refractive cylinder (0.92 ± 0.56 D and 0.78 ± 0.43 D, respectively) (P <.05); this was not the case for WTR astigmatism. Conclusions: The efficacy of femtosecond laser AK was affected by the biomechanical properties of the cornea and astigmatism type. Further studies incorporating the individual biomechanical properties of the cornea and total corneal astigmatism in a nomogram are recommended.

Original languageEnglish
Pages (from-to)202-208
Number of pages7
JournalJournal of Cataract and Refractive Surgery
Volume44
Issue number2
DOIs
StatePublished - Feb 2018

Bibliographical note

Publisher Copyright:
© 2018 ASCRS and ESCRS

Fingerprint

Dive into the research topics of 'Astigmatic correction by intrastromal astigmatic keratotomy during femtosecond laser–assisted cataract surgery: Factors in outcomes'. Together they form a unique fingerprint.

Cite this