N2 - Purpose: To retrospectively evaluate the diagnostic accuracy of ultrasonographic (US) criteria for the depiction of benign and malignant thyroid nodules by using tissue diagnosis as the reference standard. Materials and Methods: This study had institutional review board approval, and informed consent was waived. From January 2003 through June 2003, 8024 consecutive patients had undergone thyroid US at nine affiliated hospitals. A total of 831 patients (716 women, 115 men; mean age, 49.5 years ± 13.8 [standard deviation]) with 849 nodules (360 malignant, 489 benign) that were diagnosed at surgery or biopsy were included in this study. Three radiologists retrospectively evaluated the following characteristics on US images: nodule size, presence of spongiform appearance, shape, margin, echotexture, echogenicity, and presence of microcalcification, macrocalcification, or rim calcification. A χ2 test and multiple regression analysis were performed. Sensitivity, specificity, and positive and negative predictive values were obtained. Results: Statistically significant (P < .05) findings of malignancy were a taller-than-wide shape (sensitivity, 40.0%; specificity, 91.4%), a spiculated margin (sensitivity, 48.3%; specificity, 91.8%), marked hypoechogenicity (sensitivity, 41.4%; specificity, 92.2%), microcalcification (sensitivity, 44.2%; specificity, 90.8%), and macrocalcification (sensitivity, 9.7%; specificity, 96.1%). The US findings for benign nodules were isoechogenicity (sensitivity, 56.6%; specificity, 88.1%; P < .001) and a spongiform appearance (sensitivity, 10.4%; specificity, 99.7%; P < .001). The presence of at least one malignant US finding had a sensitivity of 83.3%, a specificity of 74.0%, and a diagnostic accuracy of 78.0%. For thyroid nodules with a diameter of 1 cm or less, the sensitivity of microcalcifications was lower than that in larger nodules (36.6% vs 51.4%, P < .05). Conclusion: Shape, margin, echogenicity, and presence of calcification are helpful criteria for the discrimination of malignant from benign nodules; the diagnostic accuracy of US criteria is dependent on tumor size.
AB - Purpose: To retrospectively evaluate the diagnostic accuracy of ultrasonographic (US) criteria for the depiction of benign and malignant thyroid nodules by using tissue diagnosis as the reference standard. Materials and Methods: This study had institutional review board approval, and informed consent was waived. From January 2003 through June 2003, 8024 consecutive patients had undergone thyroid US at nine affiliated hospitals. A total of 831 patients (716 women, 115 men; mean age, 49.5 years ± 13.8 [standard deviation]) with 849 nodules (360 malignant, 489 benign) that were diagnosed at surgery or biopsy were included in this study. Three radiologists retrospectively evaluated the following characteristics on US images: nodule size, presence of spongiform appearance, shape, margin, echotexture, echogenicity, and presence of microcalcification, macrocalcification, or rim calcification. A χ2 test and multiple regression analysis were performed. Sensitivity, specificity, and positive and negative predictive values were obtained. Results: Statistically significant (P < .05) findings of malignancy were a taller-than-wide shape (sensitivity, 40.0%; specificity, 91.4%), a spiculated margin (sensitivity, 48.3%; specificity, 91.8%), marked hypoechogenicity (sensitivity, 41.4%; specificity, 92.2%), microcalcification (sensitivity, 44.2%; specificity, 90.8%), and macrocalcification (sensitivity, 9.7%; specificity, 96.1%). The US findings for benign nodules were isoechogenicity (sensitivity, 56.6%; specificity, 88.1%; P < .001) and a spongiform appearance (sensitivity, 10.4%; specificity, 99.7%; P < .001). The presence of at least one malignant US finding had a sensitivity of 83.3%, a specificity of 74.0%, and a diagnostic accuracy of 78.0%. For thyroid nodules with a diameter of 1 cm or less, the sensitivity of microcalcifications was lower than that in larger nodules (36.6% vs 51.4%, P < .05). Conclusion: Shape, margin, echogenicity, and presence of calcification are helpful criteria for the discrimination of malignant from benign nodules; the diagnostic accuracy of US criteria is dependent on tumor size.
UR - http://www.scopus.com/inward/record.url?scp=45149089073&partnerID=8YFLogxK
U2 - 10.1148/radiol.2473070944
DO - 10.1148/radiol.2473070944
M3 - Article
C2 - 18403624
AN - SCOPUS:45149089073
SN - 0033-8419
VL - 247
SP - 762
EP - 770
JO - Radiology
JF - Radiology
IS - 3
ER -