Skip to main navigation Skip to search Skip to main content

Clinical and angiographic outcomes of the first Korean-made sirolimus-eluting coronary stent with abluminal bioresorbable polymer

  • Hyoung Mo Yang
  • , Kyoung Woo Seo
  • , Junghan Yoon
  • , Hyo Soo Kim
  • , Kiyuk Chang
  • , Hong Seok Lim
  • , Byoung Joo Choi
  • , So Yeon Choi
  • , Myeong Ho Yoon
  • , Seung Hwan Lee
  • , Sung Gyun Ahn
  • , Young Jin Youn
  • , Jun Won Lee
  • , Bon Kwon Koo
  • , Kyung Woo Park
  • , Han Mo Yang
  • , Jung Kyu Han
  • , Ki Bae Seung
  • , Wook Sung Chung
  • , Pum Joon Kim
  • Yoon Seok Koh, Hun Jun Park, Seung Jea Tahk
  • Ajou University
  • Yonsei University Mirae Campus
  • Catholic Univ. of Korea Coll. Med.
  • Seoul National University

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Background and Objectives: This trial evaluated the safety and efficacy of the Genoss drug-eluting coronary stent. Methods: This study was a prospective, multicenter, randomized trial with a 1:1 ratio of Genoss drug-eluting stent (DES)™ and Promus Element™. Inclusion criteria were the presence of stable angina, unstable angina, or silent ischemia. Angiographic inclusion criteria were de novo coronary stenotic lesion with diameter stenosis >50%, reference vessel diameter of 2.5-4.0 mm, and lesion length ≤40 mm. The primary endpoint was in-stent late lumen loss at 9-month quantitative coronary angiography follow-up. Secondary endpoints were in-segment late lumen loss, binary restenosis rate, death, myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis during 9 months of follow-up. Results: We enrolled 38 patients for the Genoss DES™ group and 39 patients for the Promus Element™ group. In-stent late lumen loss at 9 months was not significantly different between the 2 groups (0.11±0.25 vs. 0.16±0.43 mm, p=0.567). There was no MI or stent thrombosis in either group. The rates of death (2.6% vs. 0%, p=0.494), TLR (2.6% vs. 2.6%, p=1.000), and TVR (7.9% vs. 2.6%, p=0.358) at 9 months were not significantly different. Conclusion: This first-in-patient study of the Genoss DES™ stent showed excellent angiographic outcomes for in-stent late lumen loss and major adverse cardiac events over a 9-month follow-up.

Original languageEnglish
Pages (from-to)898-906
Number of pages9
JournalKorean Circulation Journal
Volume47
Issue number6
DOIs
StatePublished - Nov 2017

Bibliographical note

Publisher Copyright:
© 2017. The Korean Society of Cardiology.

Keywords

  • Coronary artery disease
  • Drug-eluting stents
  • Sirolimus