Background: The avascular capsule around the generator of the cardiac implantable electronic device (CIED) could be susceptible to bacterial colonization and source of infection. Capsulectomy during CIED generator replacement may be beneficial in preventing device infection, but there is a lack of evidence. Methods: This prospective randomized trial, conducted from December 2013 to December 2019, included 195 patients divided equally into two groups. In the intervention group (n = 97), capsule removal was performed on the floor of the pocket, while it was not performed in the control group (n = 98). In both groups, swab culture was performed in the pocket. The primary outcome was the occurrence of device infection requiring pocket revision. Results: A total of 195 patients were included (mean age 70.2 ± 13.6 years, 55.4% women), with an average follow-up period of 54.3 ± 28.9 months. Among 182 patients undergoing microbiological cultures of pockets, 19 (10.4%) were confirmed positive, and Staphylococcus species were identified most frequently. The primary outcome occurred in 4 (2.1%), and there was no significant difference between the two groups (3.1% vs. 1.0%, p = 0.606). Hematoma has occurred in 10 patients (3.1% vs. 7.1%, p = 0.338), one of them required wound revision. In multivariable analysis, the occurrence of hematoma was the only independent risk factor associated with device infection (HR 13.6, 95% CI 1.02–181.15, p = 0.048). Conclusions: In this long-term prospective study, capsulectomy during the replacement of the generator did not reduce the incidence of device infection. There was no association between bacterial colonization in the capsule around the generator and CIED infection. Graphical Abstract: (Figure presented.)

Original languageEnglish
Pages (from-to)1211-1217
Number of pages7
JournalJournal of Interventional Cardiac Electrophysiology
Volume67
Issue number5
DOIs
StatePublished - Aug 2024

Bibliographical note

Publisher Copyright:
© The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2024.

Keywords

  • Bacterial colonization
  • CIED (cardiac implantable electronic device)
  • Capsulectomy
  • Cardiac device infection
  • Generator replacement

Fingerprint

Dive into the research topics of 'Clinical impact of capsulectomy during cardiac implantable electronic device generator replacement: a prospective randomized trial'. Together they form a unique fingerprint.

Cite this