Skip to main navigation Skip to search Skip to main content

Clinical validation of Anyplex II HPV HR detection test for cervical cancer screening in Korea

  • Seegene Medical Foundation

Research output: Contribution to journal › Article › peer-review

23 Scopus citations

Abstract

Context. - The Anyplex II HPV HR detection kit (Seegene Inc, Seoul, Korea) is a new, multiplex, real-time polymerase chain reaction assay to detect individual 14 high-risk (HR) human papillomavirus (HPV) types in a single tube. Objective. - To evaluate the clinical performance of the HPV HR kit in predicting high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse in cervical cancer screening. Design. - We analyzed 1137 cervical samples in Huro Path medium (CelltraZone, Seoul, Korea) from Korean women. The clinical performance of the HPV HR kit was compared with Hybrid Capture 2 (Qiagen, Valencia, California) using the noninferiority score test in a routine cervical cancer screening setting. The intralaboratory and interlaboratory agreements of HPV HR were also evaluated. Results. - Overall agreement between the 2 assays was 92.4% (1051 of 1137) with a κ value of 0.787. Clinical sensitivity of HPV HR for high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse was 94.4% (95% confidence interval [CI], 89.2-99.7) and 92.5% (95% CI, 84.3-100.0), respectively. The respective values for Hybrid Capture 2 were 93.1% (95% CI, 87.2-98.9) and 87.5% (95% CI, 77.3-99.7). Clinical sensitivity and specificity of HPV HR were not inferior to those of Hybrid Capture 2 (P = .005 and P = .04, respectively). The HPV HR showed good intralaboratory and interlaboratory reproducibility at 98.0% (κ = 0.953) and 97.4% (κ = 0.940), respectively. Conclusions. - The HPV HR demonstrates comparable performance to the Hybrid Capture 2 test and can be useful for HPV-based cervical cancer screening testing.

Original languageEnglish
Pages (from-to)276-280
Number of pages5
JournalArchives of Pathology and Laboratory Medicine
Volume140
Issue number3
DOIs
StatePublished - Mar 2016

Bibliographical note

Publisher Copyright:
© 2016, College of American Pathologists. All rights reserved.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Clinical validation of Anyplex II HPV HR detection test for cervical cancer screening in Korea'. Together they form a unique fingerprint.

Cite this