TY - JOUR
T1 - Comparison of conventional magnetic resonance imaging and diffusion-weighted imaging in the differentiation of bone plasmacytoma from bone metastasis in the extremities
AU - Hwang, Hyejung
AU - Lee, Seul Ki
AU - Kim, Jee Young
N1 - Publisher Copyright:
© 2021 Société française de radiologie
PY - 2021/10
Y1 - 2021/10
N2 - Purpose: To compare conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) in the differentiation of bone plasmacytoma from bone metastasis in the extremities. Materials and methods: A total of 65 patients with 27 bone plasmacytomas (11 men; mean age, 63.6 ± 8.2 [SD] years) and 38 patients with bone metastases (20 men; mean age, 64.1 ± 11.5 [SD] years) were retrospectively included. Plasmacytomas and metastases were compared for size, peritumoral edema, signal intensity (SI), SI pattern, apparent diffusion coefficient (ADC) values and standard deviation (SD) of ADC. Receiver operating characteristic analysis with area under the curve (AUC) was used to calculate sensitivity, specificity, and accuracy of MRI and DWI for the diagnosis of plasmacytoma according to a defined cut-off value. Results: On conventional MRI, plasmacytomas showed less peritumoral edema (22% vs. 71%; P < 0.001), were more often hyperintense on T1-weighted image (48% vs. 18%; P = 0.022) and more homogeneous on T2-weighted image (78% vs. 26%; P < 0.001) and contrast-enhanced T1-weighted images (70% vs. 25%; P = 0.001) than bone metastases. Mean ADC value and SD of ADC were significantly lower in bone plasmacytomas (760.1 ± 196.9 [SD] μm2/s and 161.5 ± 62.7 [SD], respectively) than in bone metastases (1214.2 ± 382.6 [SD] μm2/s and 277.0 ± 110.3 [SD], respectively) (P < 0.001). Using an ADC value ≤ 908.3 μm2/s, DWI yielded 88% sensitivity and 78% specificity for the diagnosis of plasmacytoma. ADC value yielded best area under the curve (AUC = 0.913), followed by SD of ADC (AUC = 0.814) and homogeneity on T2-weighted images (AUC = 0.757). The combination of conventional MRI and DWI (AUC = 0.894) showed improved diagnostic performance over conventional MRI alone (AUC= 0.843) for discriminating between plasmacytoma and metastasis. Conclusion: Conventional MRI in combination with DWI can be useful to discriminate between bone plasmacytoma and bone metastasis in the extremities.
AB - Purpose: To compare conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) in the differentiation of bone plasmacytoma from bone metastasis in the extremities. Materials and methods: A total of 65 patients with 27 bone plasmacytomas (11 men; mean age, 63.6 ± 8.2 [SD] years) and 38 patients with bone metastases (20 men; mean age, 64.1 ± 11.5 [SD] years) were retrospectively included. Plasmacytomas and metastases were compared for size, peritumoral edema, signal intensity (SI), SI pattern, apparent diffusion coefficient (ADC) values and standard deviation (SD) of ADC. Receiver operating characteristic analysis with area under the curve (AUC) was used to calculate sensitivity, specificity, and accuracy of MRI and DWI for the diagnosis of plasmacytoma according to a defined cut-off value. Results: On conventional MRI, plasmacytomas showed less peritumoral edema (22% vs. 71%; P < 0.001), were more often hyperintense on T1-weighted image (48% vs. 18%; P = 0.022) and more homogeneous on T2-weighted image (78% vs. 26%; P < 0.001) and contrast-enhanced T1-weighted images (70% vs. 25%; P = 0.001) than bone metastases. Mean ADC value and SD of ADC were significantly lower in bone plasmacytomas (760.1 ± 196.9 [SD] μm2/s and 161.5 ± 62.7 [SD], respectively) than in bone metastases (1214.2 ± 382.6 [SD] μm2/s and 277.0 ± 110.3 [SD], respectively) (P < 0.001). Using an ADC value ≤ 908.3 μm2/s, DWI yielded 88% sensitivity and 78% specificity for the diagnosis of plasmacytoma. ADC value yielded best area under the curve (AUC = 0.913), followed by SD of ADC (AUC = 0.814) and homogeneity on T2-weighted images (AUC = 0.757). The combination of conventional MRI and DWI (AUC = 0.894) showed improved diagnostic performance over conventional MRI alone (AUC= 0.843) for discriminating between plasmacytoma and metastasis. Conclusion: Conventional MRI in combination with DWI can be useful to discriminate between bone plasmacytoma and bone metastasis in the extremities.
KW - Diffusion magnetic resonance imaging
KW - Extremities
KW - Magnetic resonance imaging
KW - Neoplasm metastasis
KW - Plasmacytoma
UR - http://www.scopus.com/inward/record.url?scp=85107934449&partnerID=8YFLogxK
U2 - 10.1016/j.diii.2021.05.009
DO - 10.1016/j.diii.2021.05.009
M3 - Article
C2 - 34127433
AN - SCOPUS:85107934449
SN - 2211-5684
VL - 102
SP - 611
EP - 618
JO - Diagnostic and interventional imaging
JF - Diagnostic and interventional imaging
IS - 10
ER -