N2 - Background: Qualitative hepatitis B surface antigen (HBsAg) assay kits are still commonly used in Korea where hepatitis B virus (HBV) infection is endemic. The accurate determination of HBsAg plays a crucial role in the diagnosis and prevention of HBV infection, especially in endemic areas. The aim of this study was to compare the detection sensitivities of 9 qualitative HBsAg assay kits. Methods: Seven pooled sera with HBsAg concentration ranging from 0.14 IU/mL to 29.96 IU/mL were prepared. The HBsAg concentration of each pooled serum was determined by a quantitative HBsAg assay, Architect HBsAg (Abbott Laboratories, Ireland). The fully automated immunoassay kits included Elecsys HBsAg (Roche Diagnostics, Germany) and Immulite 2000 HBsAg (DPC, USA) and the rapid tests included 5 immunochromatographic assay (ICA) kits and 2 reverse passive hemagglutination assay (RPHA) kits. Results: Elecsys HBsAg (Roche Diagnostics) showed positive result in pooled serum with HBsAg concentration of 0.14 IU/mL, but Immulite 2000 HBsAg (DPC) showed negative result in the same concentration. Although ICA kits showed variable results among different assay kits, all of them showed negative results in pooled sera with HBsAg concentration of ≤1.89 IU/mL. Two RPHA kits showed negative results in pooled sera with HBsAg concentration of ≤7.98 IU/mL. Conclusions: Although ICAs were more sensitive than RPHAs, they had variable sensitivities for HBsAg and were less sensitive than the automated immunoassay kits. Therefore, ICAs and RPHAs should be used with caution in the screening tests for HBsAg and their sensitivities need to be improved.
AB - Background: Qualitative hepatitis B surface antigen (HBsAg) assay kits are still commonly used in Korea where hepatitis B virus (HBV) infection is endemic. The accurate determination of HBsAg plays a crucial role in the diagnosis and prevention of HBV infection, especially in endemic areas. The aim of this study was to compare the detection sensitivities of 9 qualitative HBsAg assay kits. Methods: Seven pooled sera with HBsAg concentration ranging from 0.14 IU/mL to 29.96 IU/mL were prepared. The HBsAg concentration of each pooled serum was determined by a quantitative HBsAg assay, Architect HBsAg (Abbott Laboratories, Ireland). The fully automated immunoassay kits included Elecsys HBsAg (Roche Diagnostics, Germany) and Immulite 2000 HBsAg (DPC, USA) and the rapid tests included 5 immunochromatographic assay (ICA) kits and 2 reverse passive hemagglutination assay (RPHA) kits. Results: Elecsys HBsAg (Roche Diagnostics) showed positive result in pooled serum with HBsAg concentration of 0.14 IU/mL, but Immulite 2000 HBsAg (DPC) showed negative result in the same concentration. Although ICA kits showed variable results among different assay kits, all of them showed negative results in pooled sera with HBsAg concentration of ≤1.89 IU/mL. Two RPHA kits showed negative results in pooled sera with HBsAg concentration of ≤7.98 IU/mL. Conclusions: Although ICAs were more sensitive than RPHAs, they had variable sensitivities for HBsAg and were less sensitive than the automated immunoassay kits. Therefore, ICAs and RPHAs should be used with caution in the screening tests for HBsAg and their sensitivities need to be improved.
KW - HBsAg
KW - Immunochromatographic assay
KW - Reverse passive hemagglutination assay
UR - http://www.scopus.com/inward/record.url?scp=77954854852&partnerID=8YFLogxK
U2 - 10.3343/kjlm.2010.30.2.178
DO - 10.3343/kjlm.2010.30.2.178
M3 - Article
C2 - 20445337
AN - SCOPUS:77954854852
SN - 1598-6535
VL - 30
SP - 178
EP - 184
JO - Korean Journal of Laboratory Medicine
JF - Korean Journal of Laboratory Medicine
IS - 2
ER -