Deep learning-accelerated T2-weighted imaging of the prostate: Impact of further acceleration with lower spatial resolution on image quality

    Research output: Contribution to journalArticlepeer-review

    35 Scopus citations

    Abstract

    Purpose: To compare image quality in prostate MRI among standard T2-weighted imaging (T2-std), accelerated T2-weighted imaging (T2WI) with high resolution (T2-HR) and more accelerated T2WI with lower resolution (T2-LR) using both conventional reconstruction (C) and deep learning reconstruction (DL). Materials and methods: In 46 consecutive patients, T2-std, T2-HR and T2-LR were acquired in 3:32 min, 1:06 min and 0.52 min, respectively. Both reconstruction techniques (C and DL) were applied to T2-HR and T2-LR. Five sets of images (T2-std, T2-HRC, T2-LRC, T2-HRDL, and T2-LRDL) for each patient were independently evaluated by two radiologists. Quantitative analysis including the signal-to-noise ratio (SNR) and contrast ratio (CR) and qualitative analysis with a 5-point scale for the sharpness of structures, ghosting or other artifacts, noise and overall image quality were performed. Results: The SNR was not different in either the peripheral zone (PZ) or transition zone (TZ) between T2-LRDL and T2-std with the median value of 21.7 versus 22.6 in PZ and 16.5 versus 17.3 in TZ, respectively. The CR between the prostate gland and muscle was significantly lower on T2-HRC and T2-LRC than on T2-std. Most of the evaluated factors showed significantly lower scores on T2-HRC and T2-LRC than on T2-std. Although noise and overall image quality on T2-HRDL and other artifacts on T2-LRDL were rated significantly lower than on T2-std (median value 4.0 versus 4.5, P < 0.001; 4.5 versus 5.0, P = 0.001; 4.5 versus 5.0, P = 0.006, respectively), other factors did not differ between T2-std and T2-HRDL or T2-LRDL. Conclusion: DL is useful to improve image quality in accelerated T2WI of the prostate gland. Using DL, accelerated T2WI with lower spatial resolution than T2-std can be achieved with similar image quality in much shorter scan time (75.5% reduction in the acquisition time).

    Original languageEnglish
    Article number110012
    JournalEuropean Journal of Radiology
    Volume145
    DOIs
    StatePublished - Dec 2021

    Bibliographical note

    Publisher Copyright:
    © 2021 Elsevier B.V.

    Keywords

    • Deep learning reconstruction
    • Image quality
    • Magnetic resonance imaging
    • Prostate gland
    • T2-weighted image

    Fingerprint

    Dive into the research topics of 'Deep learning-accelerated T2-weighted imaging of the prostate: Impact of further acceleration with lower spatial resolution on image quality'. Together they form a unique fingerprint.

    Cite this