N2 - The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the endplate, with the intent of expanding the surface area of encapsulation. We enrolled 92 patients (92 eyes) who underwent AGV implantation. Of them, 50 patients underwent conventional surgery (termed the without-expansion group), and 42 received an additional an 8 × 6 mm pericardium graft inserted adjacent to the AGV endplate at the sub-Tenon’s space (with-expansion). The hypertensive phase was classified as mild (>21 mmHg), moderate (>25 mmHg), and severe (>30 mmHg). Six months post-surgery, the with-expansion group exhibited a lower IOP (14.90 ± 4.27 mmHg) and lower peak IOP (22.29 ± 4.95 mmHg) than the without-expansion group (17.56 ± 4.88 mmHg and 25.06 ± 6.18 mmHg, p = 0.008 and p = 0.021, respectively). The with-expansion group exhibited a relatively low rate of moderate (16.7%) and severe (4.8%) hypertensive phases compared to the without-expansion group (40.0% and 20.0%, with p = 0.014 and p = 0.031, respectively). The additional pericardium graft was associated with a reduced occurrence of moderate hypertensive phase in both univariate and multivariate analysis logistic regression analyses (p = 0.017 and p = 0.038, respectively). Endplate surface area expansion using an additional pericardium graft reduced the occurrence of moderate and severe hypertensive phases, and lower postoperative 6-month IOP could be achieved.
AB - The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the endplate, with the intent of expanding the surface area of encapsulation. We enrolled 92 patients (92 eyes) who underwent AGV implantation. Of them, 50 patients underwent conventional surgery (termed the without-expansion group), and 42 received an additional an 8 × 6 mm pericardium graft inserted adjacent to the AGV endplate at the sub-Tenon’s space (with-expansion). The hypertensive phase was classified as mild (>21 mmHg), moderate (>25 mmHg), and severe (>30 mmHg). Six months post-surgery, the with-expansion group exhibited a lower IOP (14.90 ± 4.27 mmHg) and lower peak IOP (22.29 ± 4.95 mmHg) than the without-expansion group (17.56 ± 4.88 mmHg and 25.06 ± 6.18 mmHg, p = 0.008 and p = 0.021, respectively). The with-expansion group exhibited a relatively low rate of moderate (16.7%) and severe (4.8%) hypertensive phases compared to the without-expansion group (40.0% and 20.0%, with p = 0.014 and p = 0.031, respectively). The additional pericardium graft was associated with a reduced occurrence of moderate hypertensive phase in both univariate and multivariate analysis logistic regression analyses (p = 0.017 and p = 0.038, respectively). Endplate surface area expansion using an additional pericardium graft reduced the occurrence of moderate and severe hypertensive phases, and lower postoperative 6-month IOP could be achieved.
KW - Ahmed glaucoma valve
KW - glaucoma drainage device
KW - pericardium graft
UR - http://www.scopus.com/inward/record.url?scp=85173812928&partnerID=8YFLogxK
U2 - 10.3390/jcm12196266
DO - 10.3390/jcm12196266
M3 - Article
AN - SCOPUS:85173812928
SN - 2077-0383
VL - 12
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
IS - 19
M1 - 6266
ER -