Abstract
We investigated the efficacy and safety of our novel three-step medial release technique in varus total knee arthroplasty (TKA) over time. Two hundred sixty seven consecutive varus TKAs were performed by applying the algorithmic release technique which consisted of sequential release of the deep medial collateral ligament (step 1), the semimembranosus (step 2), and multiple needle puncturing of the superficial medial collateral ligament (step 3). One hundred seventeen, 114, and 36 knees were balanced after step 1, 2, and 3 releases, respectively. There were no significant differences in changes of medial and lateral laxities between groups in over a year. Our novel stepwise medial release technique was efficacious and safe in balancing varus knees during TKA.
| Original language | English |
|---|---|
| Pages (from-to) | 1542-1547 |
| Number of pages | 6 |
| Journal | Journal of Arthroplasty |
| Volume | 30 |
| Issue number | 9 |
| DOIs | |
| State | Published - 1 Sep 2015 |
Bibliographical note
Publisher Copyright:© 2015 Elsevier Inc.
Keywords
- Medial collateral ligament
- Medial release
- Semimembranosus
- Total knee arthroplasty
- Varus deformity
Fingerprint
Dive into the research topics of 'Efficacy and Safety of a Novel Three-Step Medial Release Technique in Varus Total Knee Arthroplasty'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver