Skip to main navigation Skip to search Skip to main content

Efficacy and safety of radiofrequency ablation for benign thyroid nodules: A prospective multicenter study

  • So Lyung Jung
  • , Jung Hwan Baek
  • , Jeong Hyun Lee
  • , Young Kee Shong
  • , Jin Yong Sung
  • , Kyu Sun Kim
  • , Ducky Lee
  • , Ji Hoon Kim
  • , Seon Mi Baek
  • , Jung Suk Sim
  • , Dong Gyu Na

    Research output: Contribution to journalArticlepeer-review

    183 Scopus citations

    Abstract

    Objective: To assess the efficacy and safety of thyroid radiofrequency (RF) ablation for benign thyroid nodules by trained radiologists according to a unified protocol in a multi-center study. Materials and Methods: From 2010 to 2011, 345 nodules from 345 patients (M:F = 43:302; mean age ± SD = 46.0 ± 12.7 years, range = 15–79) who met eligibility criteria were enrolled from five institutions. At pre-ablation, the mean volume was 14.2 ± 13.2 mL (1.1–80.8 mL). For 12 months or longer after treatment, 276 lesions, consisting of 248 solid and 28 predominantly cystic nodules, were followed. All operators performed RF ablation with a cool-tip RF system and two standard techniques (a transisthmic approach and the moving-shot technique). Volume reduction at 12 months after RF ablation (the primary outcome), therapeutic success, improvement of symptoms as well as of cosmetic problems, and complications were evaluated. Multiple linear regression analysis was applied to identify factors that were independently predictive of volume reduction. Results: The mean volume reduction at 12 months was 80.3% (n = 276) and at the 24-, 36-, 48-, and 60-month follow-ups 84.3% (n = 198), 89.2% (n = 128), 91.9% (n = 57), and 95.3% (n = 6), respectively. Our therapeutic success was 97.8%. Both mean symptom and cosmetic scores showed significant improvements (p < 0.001). The rate of major complications was 1.0% (3/276). Solidity and applied energy were independent factors that predicted volume reduction. Conclusion: Radiofrequency ablation performed by trained radiologists from multiple institutions using a unified protocol and similar devices was effective and safe for treating benign thyroid nodules.

    Original languageEnglish
    Pages (from-to)167-174
    Number of pages8
    JournalKorean Journal of Radiology
    Volume19
    Issue number1
    DOIs
    StatePublished - 1 Jan 2018

    Bibliographical note

    Publisher Copyright:
    © 2018 The Korean Society of Radiology.

    Keywords

    • Intervention
    • Neoplasm
    • Nodule
    • Prospective study
    • Radiofrequency ablation
    • Thyroid
    • Tumor
    • Ultrasound

    Fingerprint

    Dive into the research topics of 'Efficacy and safety of radiofrequency ablation for benign thyroid nodules: A prospective multicenter study'. Together they form a unique fingerprint.

    Cite this