Evaluation of tissue computed tomography number changes and dosimetric shifts after conventional whole-breast irradiation in patients undergoing breast-conserving surgery

  • Joo Hwan Lee
  • , Dong Soo Lee
  • , So Hyun Park
  • , Young Kyu Lee
  • , Jeong Soo Kim
  • , Yong Seok Kim

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

The aim of this study was to assess tissue computed tomography (CT) number changes and corresponding dosimetric shifts in repeatedly performed simulation CT (re-sim CT) scans after conventionally fractionated irradiation in breast cancer patients. A total of 28 breast cancer patients who underwent breast-conserving surgery were enrolled in this study. All the patients had received 50.4 Gy of conventional whole-breast irradiation (WBI) and underwent re-sim CT scans for tumor bed boost. For evaluation of dosimetric shifts between initial and re-sim CT scans, electron boost plans in the same field size with the same monitor unit with source-to-skin distance of 100 cm were conducted. Dosimetric parameters (V105%, V103%, V100%, V98%, V95%, V90%: Vx% indicates volumes which receive X% of prescribed doses) between initial and re-sim CT scans were compared. The CT number data (CTmean, CTmax, CTmin) of the original and irradiated CT (re-sim CT) scans from each representative structure (lung, rib bone, soft tissue, muscle, etc.) were examined and recruited. CT numbers showed highly variable changes. Soft tissue CTmean and muscle CTmax/CTmin showed statistically and significantly increased values in the CT (re-sim CT) compared to the original CT scans. Rib bone CTmean/CTmin showed statistically and significantly decreased values in the re-sim CT compared to the original CT scans. Other CT number values showed no statistically significant changes. Among the dosimetric parameters, only V105% (p = 0.015, mean = 3.07 cc versus 1.63 cc) and V103% (p = 0.017, mean = 13.8 cc versus 11.9 cc) exhibited statistically increased values in the re-sim CT compared to the original CT scans. CT number changes after conventional WBI were different according to tissue component. For electron boost plans, the implementation of a re-sim CT might be helpfully considered because significant dosimetric factor changes were observed especially in the high-dose areas (hot spots: V105% and V103%).

Original languageEnglish
JournalTumor Biology
Volume40
Issue number8
DOIs
StatePublished - 1 Aug 2018

Bibliographical note

Publisher Copyright:
© The Author(s) 2018.

Keywords

  • Breast cancer
  • Hausenfield unit
  • computed tomography
  • radiotherapy
  • whole-breast irradiation

Fingerprint