Impact of a structured quantitative program on [18F]FP-CIT PET interpretation: a multicenter study of diagnostic accuracy, interrater reliability, and reader confidence

  • Byungwook Choi
  • , Seunggyun Ha
  • , Sungmin Kang
  • , Soo Jin Kwon
  • , Junik Son
  • , Shin Young Jeong
  • , Sang Woo Lee
  • , Yeong Sim Choe
  • , Donghyeon Kim
  • , Chae Moon Hong
    • Catholic University of Daegu
    • Catholic Univ. of Korea Coll. Med.
    • The Catholic University of Korea Eunpyeong St. Mary’s Hospital
    • Kyungpook National University
    • Neurophet Inc.

    Research output: Contribution to journal › Article › peer-review

    Abstract

    Objectives: This study assessed the impact of a structured quantitative analysis program on diagnostic performance, interrater reliability, and reader confidence in interpreting N-3-[18F]fluoropropyl-2β-carbomethoxy-3β-4-iodophenyl nortropane positron emission tomography ([18F]FP-CIT PET) scans to differentiate idiopathic Parkinson’s disease from essential tremor-/drug-induced parkinsonism. Methods: This retrospective multicenter study included 637 patients who underwent [18F]FP-CIT PET and brain magnetic resonance imaging scans for evaluation of Parkinsonian syndromes at 4 institutions between January 2015 and October 2022. Readers evaluated the scans qualitatively in the pre-program session and with access to quantitative parameters in the post-program session, with a 1-month minimum interval to minimize recall bias. Diagnostic performance metrics (sensitivity, specificity, accuracy), interrater reliability (Cohen’s κ), and reader confidence (low/moderate vs high) were compared. Results: Following program implementation, interrater reliability significantly improved from substantial to almost perfect (Cohen’s κ: 0.768-0.970; P < .001), and a significant shift toward high-confidence ratings was observed (P < .001). Diagnostic accuracy also significantly improved from 92.8% to 94.3% (P = .036). Although the increase in the area under the curve (0.922-0.932) did not reach statistical significance (P = .163), likely due to a ceiling effect, reader performance significantly surpassed that of the quantitative parameter alone only after program implementation, whereas it was comparable at baseline. Conclusions: These findings suggest that integrating quantitative analysis tools may improve diagnostic consistency and reliability in clinical practice. Advances in knowledge: The structured quantitative analysis program significantly improved [18F]FP-CIT PET/CT interpretation by increasing diagnostic accuracy, interrater reliability, and reader confidence.

    Original languageEnglish
    Pages (from-to)980-988
    Number of pages9
    JournalBritish Journal of Radiology
    Volume99
    Issue number1181
    DOIs
    StatePublished - May 2026

    Bibliographical note

    Publisher Copyright:
    © The Author(s) 2026. Published by Oxford University Press on behalf of the British Institute of Radiology. All rights reserved. For commercial re-use, please contact [email protected] for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact [email protected].

    Keywords

    • FP-CIT PET
    • diagnostic performance
    • idiopathic Parkinson’s disease
    • interrater reliability
    • quantitative analysis program
    • reader confidence