Iohexol versus diatrizoate for fecal/fluid tagging during CT colonography performed with cathartic preparation: comparison of examination quality

  • Bohyun Kim
  • , Seong Ho Park
  • , Gil Sun Hong
  • , Ju Hee Lee
  • , Jong Seok Lee
  • , Hyun Jin Kim
  • , Ah Young Kim
  • , Hyun Kwon Ha

    Research output: Contribution to journalArticlepeer-review

    10 Scopus citations

    Abstract

    Objective: We aimed to compare iohexol vs. diatrizoate as fecal/fluid tagging agents for computed tomography colonography (CTC) regarding examination quality. Methods: Forty prospective patients (M:F = 23:17; 63 ± 11.6 years) received CTC using 50 mL (350 mgI/mL) oral iohexol for tagging. Forty other indication-matched, age-matched, and sex-matched patients who underwent CTC using 100 mL diatrizoate for tagging and otherwise the same technique, were retrospectively identified. Two groups were compared regarding overall examination quality, per-patient and per-segment scores of colonic bubbles (0 [no bubbles] to 5 [the largest amount]), and the volume, attenuation, and homogeneity (untagged, layered, and homogeneous) of the residual colonic fluid. Results: The iohexol group demonstrated a greater amount of colonic bubbles than the diatrizoate group: mean per-patient scores ± SD of 1.2 ± 0.8 vs. 0.7 ± 0.6, respectively (p = 0.003); and rates of segments showing ≥ grade 3 bubbles of 12.9 % (85/659) vs. 1.6 % (11/695), respectively (p = 0.001). Residual colonic fluid amount standardized to the colonic volume did not significantly differ: 7.2 % ± 4.2 vs. 7.8 % ± 3.7, respectively (p = 0.544). Tagged fluid attenuation was mostly comparable between groups and the fluid was homogeneously tagged in 98.7 % (224/227) vs. 99.5 % (218/219) segments, respectively (p = 0.344). Iohexol caused more colonic bubbles when used during cathartic CTC. Otherwise, examination quality was similarly adequate with both iohexol and diatrizoate. Key Points: • When used for tagging, iohexol caused significantly more colonic bubbles than diatrizoate. • The residual colonic fluid amount did not significantly differ between iohexol and diatrizoate. • The quality of fluid tagging was similarly adequate in both iohexol and diatrizoate.

    Original languageEnglish
    Pages (from-to)1561-1569
    Number of pages9
    JournalEuropean Radiology
    Volume25
    Issue number6
    DOIs
    StatePublished - 1 Jun 2015

    Bibliographical note

    Publisher Copyright:
    © 2015, European Society of Radiology.

    Keywords

    • Cathartics
    • Colonography
    • Computed tomographic
    • Diatrizoate meglumine
    • Intestine
    • Iohexol
    • Large

    Fingerprint

    Dive into the research topics of 'Iohexol versus diatrizoate for fecal/fluid tagging during CT colonography performed with cathartic preparation: comparison of examination quality'. Together they form a unique fingerprint.

    Cite this