Skip to main navigation Skip to search Skip to main content

Long-Term Changes in Thecal Sac Compression and Decreased Cerebrospinal Fluid Space Following Paddle Lead Spinal Cord Stimulation at T9: A Long-Term Follow-Up via Three-Dimensional Myelographic Computed Tomography

  • The Catholic University of Korea Eunpyeong St. Mary’s Hospital

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

Objectives: To investigate the long-term changes in thecal sac compression following T9 paddle lead spinal cord stimulation (SCS) using three-dimensional myelographic computed tomography (CT). Materials and Methods: Seventeen patients with five-column paddle lead SCS at T9 underwent three-dimensional myelographic CT scans preoperatively, immediately after surgery, and after an average of 11 months. The cross-sectional areas of thecal sac and spinal cord and the widths of anterior and posterior cerebrospinal fluid (CSF) spaces were repeatedly measured and compared. The contact angle of the lead with long-term pain relief was assessed. Results: The cross-sectional areas of thecal sac and spinal cord decreased significantly after lead placement (30.47 ± 9.21% and 4.71 ± 9.84%, respectively). Even after 11 months, a significant reduction was found with the preoperative values (17.97 ± 12.32% and 2.88 ± 7.09%). The widths of anterior and posterior CSF spaces decreased significantly after surgery (43.53 ± 13.17% and 57.13 ± 13.17%, respectively) and the severe decrease persisted long-term (29.13 ± 21.54% and 50.99 ± 16.07%). The average pain relief was 42.27 ± 17.50% with no correlation between the rate of reduction in cross-sectional areas of thecal sac and the widths of CSF spaces. Conclusions: Significant early reduction and late partial restoration occurred in the thecal sac and spinal cord and the width of the anterior and posterior CSF spaces in the T9 5-column paddle lead SCS. Thecal sac compromise was expected to some extent after paddle lead implantation, but the degree is significant, and the cross-sectional area of the spinal cord as well as the thecal sac is affected. Fortunately, these anatomical changes did not cause any clinical problems except for intercostal root irritation. The shape and flat contours of the five-column paddle leads clearly affected the results.

Original languageEnglish
Pages (from-to)763-774
Number of pages12
JournalNeuromodulation
Volume25
Issue number5
DOIs
StatePublished - Jul 2022

Bibliographical note

Publisher Copyright:
© 2022 International Neuromodulation Society

Keywords

  • Cerebrospinal fluid
  • paddle lead
  • spinal cord
  • spinal cord stimulation
  • thecal sac

Fingerprint

Dive into the research topics of 'Long-Term Changes in Thecal Sac Compression and Decreased Cerebrospinal Fluid Space Following Paddle Lead Spinal Cord Stimulation at T9: A Long-Term Follow-Up via Three-Dimensional Myelographic Computed Tomography'. Together they form a unique fingerprint.

Cite this