Abstract
Aim: In South Korea, the law concerning automated external defibrillators (AEDs) states that they should be installed in specific places including apartment complexes. This study was conducted to investigate the current status and effectiveness of installation and usage of AEDs in South Korea. Methods: Installation and usage of AEDs in South Korea is registered in the National Emergency Medical Center (NEMC) database. Compared were the installed number, usage, and annual rate of AED use according to places of installation. All data were obtained from the NEMC database. Results: After excluding AEDs installed in ambulances or fire engines (n = 2,003), 36,498 AEDs were registered in South Korea from 1998 through 2018. A higher number of AEDs were installed in places required by the law compared with those not required by the law (20,678 [56.7%] vs. 15,820 [43.3%]; P <.001). Among them, 11,318 (31.0%) AEDs were installed in apartment complexes. The overall annual rate of AED use was 0.38% (95% CI, 0.33-0.44). The annual rate of AED use was significantly higher in places not required by the law (0.62% [95% CI, 0.52-0.72] versus 0.21% [95% CI, 0.16-0.25]; P <.001). The annual rate of AED use in apartment complexes was 0.13% (95% CI, 0.08-0.17). Conclusion: There were significant mismatches between the number of installed AEDs and the annual rate of AED use among places. To optimize the benefit of AEDs in South Korea, changes in the policy for selecting AED placement are needed.
| Original language | English |
|---|---|
| Pages (from-to) | 183-188 |
| Number of pages | 6 |
| Journal | Prehospital and Disaster Medicine |
| Volume | 36 |
| Issue number | 2 |
| DOIs | |
| State | Published - Apr 2021 |
Bibliographical note
Publisher Copyright:© The Author(s), 2021. Published by Cambridge University Press on behalf of the World Association for Disaster and Emergency Medicine.
Keywords
- South Korea
- automated external defibrillators
- electric defibrillation
- law
- out-of-hospital cardiac arrest
Fingerprint
Dive into the research topics of 'Mismatches between the Number of Installed Automated External Defibrillators and the Annual Rate of Automated External Defibrillator Use among Places'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver