Skip to main navigation Skip to search Skip to main content

Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels

  • Yon Kwon Ihn
  • , Bum soo Kim
  • , Hae Woong Jeong
  • , Sang Hyun Suh
  • , Yoo Dong Won
  • , Young Jun Lee
  • , Dong Joon Kim
  • , Pyong Jeon
  • , Chang Woo Ryu
  • , Sang il Suh
  • , Dae Seob Choi
  • , See Sung Choi
  • , Sang Heum Kim
  • , Jun Soo Byun
  • , Jieun Rho
  • , Yunsun Song
  • , Woo Sang Jeong
  • , Noah Hong
  • , Sung Hyun Baik
  • , Jeong Jin Park
  • Soo Mee Lim, Jung Jae Kim, Woong Yoon
    • The Catholic University of Korea, St. Vincent's Hospital
    • Inje University
    • Yonsei University
    • Uijeongbu St. Mary's Hospital
    • Hanyang University
    • Samsung Medical Center, Sungkyunkwan university
    • Kyung Hee University
    • Korea University
    • Gyeongsang National University
    • Wonkwang University
    • CHA University
    • Chung-Ang University
    • Pusan National University
    • University of Ulsan
    • Ajou University
    • Seoul National University
    • Konkuk University
    • Ewha Womans University
    • Chonnam National University

    Research output: Contribution to journalArticlepeer-review

    20 Scopus citations

    Abstract

    Purpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL). Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution. Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, Ihn YK et al. Reference Doses for Interventional Neuroradiology Procedures in Korea and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group. Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs.

    Original languageEnglish
    Pages (from-to)240-251
    Number of pages12
    JournalNeurointervention
    Volume16
    Issue number3
    DOIs
    StatePublished - Nov 2021

    Bibliographical note

    Publisher Copyright:
    © 2021 Korean Society of Interventional Neuroradiology

    Keywords

    • Cerebral angiography
    • Diagnostic reference levels
    • Intracra-nial aneurysm
    • Intracranial arteriovenous malformation
    • Radiation monitoring
    • Thrombectomy

    Fingerprint

    Dive into the research topics of 'Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels'. Together they form a unique fingerprint.

    Cite this