TY - JOUR
T1 - Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures
AU - Jeong, Jae Jung
AU - Park, Sang Eun
AU - Lee, Hwan Hee
AU - Ji, Jong Hun
AU - Park, Min Sik
AU - Park, Yong Taek
N1 - Publisher Copyright:
© 2019 The Author(s).
PY - 2019/8/17
Y1 - 2019/8/17
N2 - Background: Our hypothesis was that minimally invasive plate osteosynthesis (MIPO) using long philos plate (LPP) would show better clinical and radiological outcomes and less complications than narrow locking compression plate (NLCP) for spiral humerus shaft fractures with or without metaphyseal fracture extension. Methods: From January 2009 to May 2016, we retrospectively studied 35 patients who underwent MIPO for spiral humerus shaft fractures with or without metaphyseal fracture extension (AO classification 12 A, B, C except A3). Eighteen patients underwent MIPO with a 4.5 mm NLCP (group I) in the early period of this study, while 17 patients underwent MIPO with LPP (group II) in the later period. Range of motion (ROM), pre- and post-operative anteroposterior (AP) and lateral angulation of the fracture, operation time, amount of bleeding, and functional outcomes including American Shoulder and Elbow Surgeons score, University of California at Los Angeles score, and Simple Shoulder Test score were analyzed at the final follow up. Results: All patients had complete bony union and achieved satisfactory functional outcomes except 2 patients. In LPP group, better outcomes in postoperative fracture angulation on X-ray and operation time (p < 0.05) were shown. But, two revision surgery with NLCP and bone graft was performed owing to 2 metal failures. Conclusions: In spiral humeral shaft fractures, LPP group showed better fracture reduction on X-ray and shorter operation time except metal failure owing to weak fixation. Even though MIPO technique using LPP is easier and more accurate reduction method, rigid fixation should be considered.
AB - Background: Our hypothesis was that minimally invasive plate osteosynthesis (MIPO) using long philos plate (LPP) would show better clinical and radiological outcomes and less complications than narrow locking compression plate (NLCP) for spiral humerus shaft fractures with or without metaphyseal fracture extension. Methods: From January 2009 to May 2016, we retrospectively studied 35 patients who underwent MIPO for spiral humerus shaft fractures with or without metaphyseal fracture extension (AO classification 12 A, B, C except A3). Eighteen patients underwent MIPO with a 4.5 mm NLCP (group I) in the early period of this study, while 17 patients underwent MIPO with LPP (group II) in the later period. Range of motion (ROM), pre- and post-operative anteroposterior (AP) and lateral angulation of the fracture, operation time, amount of bleeding, and functional outcomes including American Shoulder and Elbow Surgeons score, University of California at Los Angeles score, and Simple Shoulder Test score were analyzed at the final follow up. Results: All patients had complete bony union and achieved satisfactory functional outcomes except 2 patients. In LPP group, better outcomes in postoperative fracture angulation on X-ray and operation time (p < 0.05) were shown. But, two revision surgery with NLCP and bone graft was performed owing to 2 metal failures. Conclusions: In spiral humeral shaft fractures, LPP group showed better fracture reduction on X-ray and shorter operation time except metal failure owing to weak fixation. Even though MIPO technique using LPP is easier and more accurate reduction method, rigid fixation should be considered.
KW - Long philos plate
KW - Minimally invasive plate osteosynthesis (MIPO)
KW - Narrow locking compression plate
KW - Spiral humeral shaft fractures
UR - http://www.scopus.com/inward/record.url?scp=85070968940&partnerID=8YFLogxK
U2 - 10.1186/s12891-019-2757-z
DO - 10.1186/s12891-019-2757-z
M3 - Article
C2 - 31421675
AN - SCOPUS:85070968940
SN - 1471-2474
VL - 20
JO - BMC Musculoskeletal Disorders
JF - BMC Musculoskeletal Disorders
IS - 1
M1 - 381
ER -