Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: A feasibility study for the assessment of dural arteriovenous fistula

    Research output: Contribution to journalArticlepeer-review

    24 Scopus citations

    Abstract

    Introduction: This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Methods: Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. Results: All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. Conclusion: NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage.

    Original languageEnglish
    Pages (from-to)305-314
    Number of pages10
    JournalNeuroradiology
    Volume56
    Issue number4
    DOIs
    StatePublished - Apr 2014

    Keywords

    • Dural arteriovenous fistula
    • Magnetic resonance angiography
    • Non-contrast enhanced
    • Time resolved
    • Variable flip angle

    Fingerprint

    Dive into the research topics of 'Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: A feasibility study for the assessment of dural arteriovenous fistula'. Together they form a unique fingerprint.

    Cite this