Performance of the Dimension TAC assay and comparison of multiple platforms for the measurement of tacrolimus

  • Eun Jung Cho
  • , Dae Hyun Ko
  • , Woochang Lee
  • , Sail Chun
  • , Hae Kyung Lee
  • , Won Ki Min
  • The Catholic University of Korea, College of Medicine
  • University of Ulsan
  • Hallym University

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background: Therapeutic monitoring of tacrolimus is essential for reducing organ rejection and adverse effects. The measurement of tacrolimus in whole blood is taken by many automated platforms. We evaluated the analytical performance of the Dimension TAC assay, which is an upgraded reagent from the previous Dimension TACR assay. Methods: The evaluations involved determination of precision, linearity, detection capability, and reagent lot-to-lot variability between three lot numbers. Correlation studies were conducted using the Dimension TACR assay, Architect, Elecsys assay, and MassTrak LC-MS/MS. Results: The total coefficient of variation was below 10%. Acceptable linearity was observed in their respective reportable ranges. The limit of blank, limit of detection, and limit of quantification were 0.29, 0.47, and 0.81 ng/mL, respectively. Correlation analysis indicated that the Dimension TAC assay results were comparable to that of the Dimension TACR assay, Architect, and Elecsys results in liver and heart transplant patients. In kidney transplant patients, the Dimension TAC assay showed the poor correlation with Architect and Elecsys. The results from these assays were slightly higher than that of MassTrak. We found little lot-to-lot reagent variation among the reagents evaluated. Conclusion: The overall analytical performance of the Dimension TAC assay is acceptable for therapeutic monitoring in clinical practice. Our study that compared different platforms may provide some useful information regarding which test method to use.

Original languageEnglish
Article numbere22357
JournalJournal of Clinical Laboratory Analysis
Volume32
Issue number4
DOIs
StatePublished - May 2018

Bibliographical note

Publisher Copyright:
© 2017 Wiley Periodicals, Inc.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Dimension TAC assay
  • immunosuppressive agent
  • performance evaluation
  • tacrolimus
  • transplant