Skip to main navigation Skip to search Skip to main content

Reappraisal of Pediatric Diastatic Skull Fractures in the 3-Dimensional CT Era: Clinical Characteristics and Comparison of Diagnostic Accuracy of Simple Skull X-Ray, 2-Dimensional CT, and 3-Dimensional CT

  • Sook Young Sim
  • , Hyun Gi Kim
  • , Soo Han Yoon
  • , Jong Wook Choi
  • , Sung Min Cho
  • , Mi Sun Choi
  • Inje University
  • Ajou University
  • Yonsei University Mirae Campus

Research output: Contribution to journalArticlepeer-review

17 Scopus citations

Abstract

Background Diastatic skull fractures (DSFs) in children are difficult to detect in skull radiographs before they develop into growing skull fractures; therefore, little information is available on this topic. However, recent advances in 3-dimensional (3D) computed tomography (CT) imaging technology have enabled more accurate diagnoses of almost all forms of skull fracture. The present study was undertaken to document the clinical characteristics of DSFs in children and to determine whether 3D CT enhances diagnostic accuracy. Methods Two hundred and ninety-two children younger than 12 years with skull fractures underwent simple skull radiography, 2-dimensional (2D) CT, and 3DCT. Results were compared with respect to fracture type, location, associated lesions, and accuracy of diagnosis. Results DSFs were diagnosed in 44 (15.7%) of children with skull fractures. Twenty-two patients had DSFs only, and the other 22 had DSFs combined with compound or mixed skull fractures. The most common fracture locations were the occipitomastoid (25%) and lambdoid (15.9%). Accompanying lesions consisted of subgaleal hemorrhages (42/44), epidural hemorrhages (32/44), pneumocephalus (17/44), and subdural hemorrhages (3/44). A total of 17 surgical procedures were performed on 15 of the 44 patients. Fourteen and 19 patients were confirmed to have DSFs by skull radiography and 2D CT, respectively, but 3D CT detected DSFs in 43 of the 44 children (P < 0.001). Conclusion 3D CT was found to be markedly superior to skull radiography or 2D CT for detecting DSFs. This finding indicates that 3D CT should be used routinely rather than 2D CT for the assessment of pediatric head trauma.

Original languageEnglish
Pages (from-to)399-406
Number of pages8
JournalWorld Neurosurgery
Volume108
DOIs
StatePublished - Dec 2017

Bibliographical note

Publisher Copyright:
© 2017 Elsevier Inc.

Keywords

  • CT
  • Diagnosis
  • Diastatic fracture
  • Head trauma
  • Pediatric
  • Skull fracture

Fingerprint

Dive into the research topics of 'Reappraisal of Pediatric Diastatic Skull Fractures in the 3-Dimensional CT Era: Clinical Characteristics and Comparison of Diagnostic Accuracy of Simple Skull X-Ray, 2-Dimensional CT, and 3-Dimensional CT'. Together they form a unique fingerprint.

Cite this