Skip to main navigation Skip to search Skip to main content

Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses

  • Byoung Sup Sohn
  • , Seong Joo Heo
  • , Jai Young Koak
  • , Seong Kyun Kim
  • , Su Young Lee
  • Seoul National University

Research output: Contribution to journal › Article › peer-review

12 Scopus citations

Abstract

Purpose: This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. Materials and methods: Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. Results: The mean strain values (MSV) for the working sides were 151.83 με, 176.23 με, and 131.07 με for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 με, 72.64 με, and 98.93 με for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). Conclusion: The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01).

Original languageEnglish
Pages (from-to)1-9
Number of pages9
JournalJournal of Advanced Prosthodontics
Volume3
Issue number1
DOIs
StatePublished - 2011

Keywords

  • Implant-supported fixed prosthesis
  • MTS machine
  • Occlusion type
  • Strain

Fingerprint

Dive into the research topics of 'Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses'. Together they form a unique fingerprint.