Abstract

Purpose: Articles evaluating radiofrequency (RF) safety are insufficient. Thus, the purpose of this study was to investigate RF safety during biportal endoscopic lumbar decompressive laminotomy by measuring epidural temperature after RF use. Methods: Both in vitro cadaveric study and in vivo study were performed. The epidural temperature was measured at epidural space after RF use in three cadavers. The epidural temperature was measured and analysed according to RF mode, RF power, RF usage time, and saline irrigation patency. In the in vivo study, the epidural temperature was measured after biportal endoscopic surgery. Epidural temperatures were measured around ipsilateral and contralateral traversing nerve roots after 1-s use of RF. Results: In the in vivo study, epidural space temperature was increased by 0.31 ± 0.16 °C ipsilaterally and 0.29 ± 0.09° contralaterally after RF use in coagulation mode 1. The epidural temperature of epidural space was increased by 0.21 ± 0.13 °C ipsilaterally and 0.15 ± 0.21 °C contralaterally after RF use in high mode 2. In the in vitro study, epidural temperature was significantly increased with a long duration of RF use and a poor patency of irrigation fluid. Conclusion: The use of RF in biportal endoscopic spine surgery might be safe. In order to reduce indirect thermal injuries caused by RF use, it might be necessary to reduce RF use time and maintain continuous saline irrigation patency well.

Original languageEnglish
Pages (from-to)2769-2775
Number of pages7
JournalEuropean Spine Journal
Volume32
Issue number8
DOIs
StatePublished - Aug 2023

Bibliographical note

Publisher Copyright:
© 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Keywords

  • Biportal endoscopy
  • Epidural
  • Radiofrequency
  • Safety
  • Temperature

Fingerprint

Dive into the research topics of 'Temperature change of epidural space by radiofrequency use in biportal endoscopic lumbar surgery: safety evaluation of radiofrequency'. Together they form a unique fingerprint.

Cite this