Abstract
Purpose: The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. Methods: From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. Results: The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. Conclusions: The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.
Original language | English |
---|---|
Pages (from-to) | 450-454 |
Number of pages | 5 |
Journal | CardioVascular and Interventional Radiology |
Volume | 40 |
Issue number | 3 |
DOIs | |
State | Published - 1 Mar 2017 |
Bibliographical note
Publisher Copyright:© 2016, Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE).
Keywords
- Central venous access
- Implantable chest port
- Monorail technique