Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: Comparison with two-dimensional fast spin-echo T2-weighted sequences

Hee Jin Park, So Yeon Lee, Noh Hyuck Park, Jin Hwan Ahn, Eun Chul Chung, Sung Jun Kim, Jang Gyu Cha

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Background There has been no comparison study to assess the diagnostic efficacy of additional anterior cruciate ligament (ACL) views in three-dimensional (3D) volume isotropic turbo spin-echo acquisition (VISTA) and two-dimensional (2D) fast spin-echo (FSE) T2-weighted (T2W) images for the diagnosis of ACL tear. Purpose To compare the diagnostic performances of additional ACL views on VISTA with those on the 2D FSE T2W images. Material and Methods This retrospective study included 78 patients who were suspected to have ACL injury and underwent both 2D TSE T2W magnetic resonance imaging (MRI) and 3D VISTA MRI of the knee between November 2012 and March 2013. The diagnostic performance of each oblique sagittal and coronal view and the combined images was evaluated for sensitivity, specificity, and accuracy for diagnosing an ACL tear. The arthroscopically and clinically confirmed diagnoses were used as the reference standard. The values were statistically analyzed using the McNemar test. Results The inter-observer agreement between two readers of the additional ACL views on 3D VISTA and 2D FSE T2W images were substantial on 2D FSE images and nearly concurred on the VISTA image. When considering both views of the oblique sagittal and coronal images, the inter-observer agreement between readers nearly concurred. There were no statistically significant differences in the sensitivity, specificity, and accuracy between 2D FSE images and VISTA images. Conclusion The performance of the additional ACL view on 3D VISTA MRI is comparable to that of 2D FSE T2W MRI in the diagnosis of ACL tear though the image quality of the 3D VISTA MRI is not equal to that of 2D FSE MRI.

Original languageEnglish
Pages (from-to)1372-1379
Number of pages8
JournalActa Radiologica
Volume57
Issue number11
DOIs
StatePublished - 1 Nov 2016

Bibliographical note

Publisher Copyright:
© The Foundation Acta Radiologica 2015.

Keywords

  • 3D isotropic
  • anterior cruciate ligament (ACL)
  • knee
  • Magnetic resonance imaging (MRI)
  • VISTA

Fingerprint

Dive into the research topics of 'Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: Comparison with two-dimensional fast spin-echo T2-weighted sequences'. Together they form a unique fingerprint.

Cite this