Skip to main navigation Skip to search Skip to main content

Tissue characterization using an electrical bioimpedance spectroscopy-based multi-electrode probe to screen for cervical intraepithelial neoplasia

  • Tong In Oh
  • , Min Ji Kang
  • , You Jeong Jeong
  • , Tingting Zhang
  • , Seung Geun Yeo
  • , Dong Choon Park
  • Kyung Hee University
  • The Catholic University of Korea, College of Medicine

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

The successful management of cervical intraepithelial neoplasia (CIN) with proper screening and treatment methods could prevent cervical cancer progression. We propose a bioimpedance spectroscopic measurement device and a multi-electrode probe as an independent screening tool for CIN. To evaluate the performance of this screening method, we enrolled 123 patients, including 69 patients with suspected CIN and 54 control patients without cervical dysplasia who underwent a hysterectomy for benign disease (non-CIN). Following conization, the electrical properties of the excised cervical tissue were characterized using an electrical bioimpedance spectroscopy-based multi-electrode probe. Twenty-eight multifrequency voltages were collected through the two concentric array electrodes via a sensitivity-optimized measurement protocol based on an electrical energy concentration method. The electrical properties of the CIN and non-CIN groups were compared with the results of the pathology reports. Reconstructed resistivity tended to decrease in the CIN and non-CIN groups as frequency increased. Reconstructed resistivity from 625 Hz to 50 kHz differed significantly between the CIN and non-CIN groups (p < 0.001). Using 100 kHz as the reference, the difference between the CIN and non-CIN groups was significant. Based on the difference in reconstructed resistivity between 100 kHz and the other frequencies, this method had a sensitivity of 94.3%, a specificity of 84%, and an accuracy of 90% in CIN screening. The feasibility of noninvasive CIN screening was confirmed through the difference in the frequency spectra evaluated in the excised tissue using the electrical bioimpedance spectroscopy-based multi-electrode screening probe.

Original languageEnglish
Article number2354
JournalDiagnostics
Volume11
Issue number12
DOIs
StatePublished - Dec 2021

Bibliographical note

Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bioimpedance spectroscopy
  • CIN
  • Cancer screening
  • Electrical impedance spectrum
  • Multi-electrode screening probe