Skip to main navigation Skip to search Skip to main content

Utility of dual-energy CT-based monochromatic imaging in the assessment of myocardial delayed enhancement in patients with cardiomyopathy

  • Suyon Chang
  • , Kyunghwa Han
  • , Jong Chan Youn
  • , Dong Jin Im
  • , Jin Young Kim
  • , Young Joo Suh
  • , Yoo Jin Hong
  • , Jin Hur
  • , Young Jin Kim
  • , Byoung Wook Choi
  • , Hye Jeong Lee
  • Yonsei University

Research output: Contribution to journal › Article › peer-review

61 Scopus citations

Abstract

Purpose: To investigate the diagnostic utility of dual-energy computed tomography (CT)-based monochromatic imaging for myocardial delayed enhancement (MDE) assessment in patients with cardiomyopathy. Materials and Methods: The institutional review board approved this prospective study, and informed consent was obtained from all participants who were enrolled in the study. Forty patients (27 men and 13 women; mean age, 56 years ± 15 [standard deviation]; age range, 22-81 years) with cardiomyopathy underwent cardiac magnetic resonance (MR) imaging and dual-energy CT. Conventional (120-kV) and monochromatic (60-, 70-, and 80-keV) images were reconstructed from the dual-energy CT acquisition. Subjective quality score, contrast-to-noise ratio (CNR), and beam-hardening artifacts were compared pairwise with the Friedman test at post hoc analysis. With cardiac MR imaging as the reference standard, diagnostic performance of dual-energy CT in MDE detection and its predictive ability for pattern classification were compared pairwise by using logistic regression analysis with the generalized estimating equation in a per-segment analysis. The Bland-Altman method was used to find agreement between cardiac MR imaging and CT in MDE quantification. Results: Among the monochromatic images, 70-keV CT images resulted in higher subjective quality (mean score, 3.38 ± 0.54 vs 3.15 ± 0.43; P =.0067), higher CNR (mean, 4.26 ± 1.38 vs 3.93 ± 1.33; P =.0047), and a lower value for beam-hardening artifacts (mean, 3.47 ± 1.56 vs 4.15 ± 1.67; P <.0001) when compared with conventional CT. When compared with conventional CT, 70-keV CT showed improved diagnostic performance for MDE detection (sensitivity, 94.6% vs 90.4% [P =.0032]; specificity, 96.0% vs 94.0% [P =.0031]; and accuracy, 95.6% vs 92.7% [P <.0001]) and improved predictive ability for pattern classification (subendocardial, 91.5% vs 84.3% [P =.0111]; epicardial, 94.3% vs 73.5% [P =.0001]; transmural, 93.0% vs 77.7% [P =.0018]; mesocardial, 85.4% vs 69.2% [P =.0047]; and patchy. 84.4% vs 78.4% [P =.1514]). For MDE quantification, 70-keV CT showed a small bias 0.1534% (95% limits of agreement: 24.7013, 5.0080). Conclusion: Dual-energy CT-based 70-keV monochromatic images improve MDE assessment in patients with cardiomyopathy via improved image quality and CNR and reduced beam-hardening artifacts when compared with conventional CT images.

Original languageEnglish
Pages (from-to)442-451
Number of pages10
JournalRadiology
Volume287
Issue number2
DOIs
StatePublished - May 2018

Bibliographical note

Publisher Copyright:
© RSNA, 2018.

Fingerprint

Dive into the research topics of 'Utility of dual-energy CT-based monochromatic imaging in the assessment of myocardial delayed enhancement in patients with cardiomyopathy'. Together they form a unique fingerprint.

Cite this