Skip to main navigation Skip to search Skip to main content

Virtual in-silico modeling guided catheter ablation predicts effective linear ablation lesion set for longstanding persistent atrial fibrillation: Multicenter prospective randomized study

  • Jaemin Shim
  • , Minki Hwang
  • , Jun Seop Song
  • , Byounghyun Lim
  • , Tae Hoon Kim
  • , Boyoung Joung
  • , Sung Hwan Kim
  • , Yong Seog Oh
  • , Gi Byung Nam
  • , Young Keun On
  • , Seil Oh
  • , Young Hoon Kim
  • , Hui Nam Pak
  • Korea University
  • Yonsei University
  • University of Ulsan
  • Sungkyunkwan University
  • Seoul National University

Research output: Contribution to journal › Article › peer-review

44 Scopus citations

Abstract

Objective: Radiofrequency catheter ablation for persistent atrial fibrillation (PeAF) still has a substantial recurrence rate. This study aims to investigate whether an AF ablation lesion set chosen using in-silico ablation (V-ABL) is clinically feasible and more effective than an empirically chosen ablation lesion set (Em-ABL) in patients with PeAF. Methods: We prospectively included 108 patients with antiarrhythmic drug-resistant PeAF (77.8% men, age 60.8 ± 9.9 years), and randomly assigned them to the V-ABL (n = 53) and Em-ABL (n = 55) groups. Five different in-silico ablation lesion sets [1 pulmonary vein isolation (PVI), 3 linear ablations, and 1 electrogram-guided ablation] were compared using heart-CT integrated AF modeling. We evaluated the feasibility, safety, and efficacy of V-ABL compared with that of Em-ABL. Results: The pre-procedural computing time for five different ablation strategies was 166 ± 11 min. In the Em-ABL group, the earliest terminating blinded in-silico lesion set matched with the Em-ABL lesion set in 21.8%. V-ABL was not inferior to Em-ABL in terms of procedure time (p = 0.403), ablation time (p = 0.510), and major complication rate (p = 0.900). During 12.6 ± 3.8 months of follow-up, the clinical recurrence rate was 14.0% in the V-ABL group and 18.9% in the Em-ABL group (p = 0.538). In Em-ABL group, clinical recurrence rate was significantly lower after PVI+posterior box+anterior linear ablation, which showed the most frequent termination during in-silico ablation (log-rank p = 0.027). Conclusions: V-ABL was feasible in clinical practice, not inferior to Em-ABL, and predicts the most effective ablation lesion set in patients who underwent PeAF ablation.

Original languageEnglish
Article number792
JournalFrontiers in Physiology
Volume8
Issue numberOCT
DOIs
StatePublished - 11 Oct 2017

Bibliographical note

Publisher Copyright:
© 2017 Shim, Hwang, Song, Lim, Kim, Joung, Kim, Oh, Nam, On, Oh, Kim and Pak.

Keywords

  • Atrial fibrillation
  • Catheter ablation
  • In-silico modeling
  • Recurrence
  • Virtual ablation

Fingerprint