Skip to main navigation Skip to search Skip to main content

Volumetric modulated arc therapy for carotid sparing in the management of early glottic cancer

  • Young Suk Kim
  • , Jaegi Lee
  • , Jong In Park
  • , Wonmo Sung
  • , Sol Min Lee
  • , Gwi Eon Kim
  • Jeju National University
  • Seoul National University

Research output: Contribution to journal › Article › peer-review

17 Scopus citations

Abstract

Purpose: Radiotherapy of the neck is known to cause carotid artery stenosis. We compared the carotid artery dose received between volumetric modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (IMRT) plans in patients with early glottic cancer. Materials and Methods: Twenty-one early glottic cancer patients who previously underwent definitive radiotherapy were selected for this study. For each patient, double arc VMAT, 8-field IMRT, 3-dimensional conformal radiotherapy (3DCRT), and lateral parallel-opposed photon field radiotherapy (LPRT) plans were created. The 3DCRT plan was generated using lateral parallel-opposed photon fields plus an anterior photon field. VMAT and IMRT treatment plan optimization was performed under standardized conditions to obtain adequate target volume coverage and spare the carotid artery. Dose-volume specifications for the VMAT, IMRT, 3DCRT, and LPRT plans were calculated with radiotherapy planning system. Monitor units (MUs) and delivery time were measured to evaluate treatment efficiency. Results: Target volume coverage and homogeneity results were comparable between VMAT and IMRT; however, VMAT was superior to IMRT for carotid artery dose sparing. The mean dose to the carotid arteries in double arc VMAT was reduced by 6.8% compared to fixed-field IMRT (p < 0.001). The MUs for VMAT and IMRT were not significantly different (p = 0.089). VMAT allowed an approximately two-fold reduction in treatment delivery time in comparison to IMRT (3 to 5 minutes vs. 5 to 10 minutes). Conclusion: VMAT resulted in a lower carotid artery dose compared to conventional fixed-field IMRT, and maintained good target coverage in patients with early glottic cancer.

Original languageEnglish
Pages (from-to)18-25
Number of pages8
JournalRadiation Oncology Journal
Volume34
Issue number1
DOIs
StatePublished - Mar 2016

Bibliographical note

Publisher Copyright:
© 2016. The Korean Society for Radiation Oncology.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Cancer
  • Carotid arteries
  • Glottis
  • Intensity-modulated radiotherapy
  • Volumetric modulated arc therapy

Fingerprint

Dive into the research topics of 'Volumetric modulated arc therapy for carotid sparing in the management of early glottic cancer'. Together they form a unique fingerprint.

Cite this